TIPS & HINTS
When programming keys, please note the following:
The transponder aerial has a resistance of 21.5 Ohms
The immobiliser control unit does not return any information to the
tester about the key programming procedure, therefore it is possible
to input an incorrect security code and continue through the pro-
gramming procedure.
When programming a key, the horn will sound for 0.2 second to sig-
nify the key programming action.
Once the first key has been programmed you should turn the ignition
on with a second key and wait for 10 seconds, the horn should again
sound- if it doesn't, switch on the HRW (Heated Rear Window
Switch) to complete the programming phase.
NOTE :-2 keys must be programmed to close the procedure.